Answers are grounded in this paper and cite their sources.
Computer simulations are employed to assess the effects of near‐source ground motions on base‐isolated buildings that meet the provisions of the 1997 Uniform Building Code . A six‐story base‐isolated building designed for N v = 1.6 exhibits essentially elastic structural behavior when subjected to six actual ground motions containing strong near‐source effects. However, two simulated records, one intended to represent the most severe motions from the 1994 Northridge earthquake and the other a strong motion from a hypothetical M w 7.0 thrust earthquake produce larger responses well into the nonlinear range. In addition, a 113 cm ground displacement pulse of three‐second duration, which is close to the period of the isolated buildings, causes story drifts of nearly 5% for the N v = 1.6 design and over 2% for a stronger N v = 2 design. Such drifts are effectively reduced when supplemental dampers are added alongside the isolators. The original N v = 1.6 design with supplemental damping in the amount of 20% of critical experiences only 1.3% drift for the same three‐second ground displacement pulse.
No takes yet. Share an insight, caveat, or question.
Hall et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: