Why the study?
High-level spinal anesthesia for cesarean section can cause significant hemodynamic changes, and it was hypothesized that baseline hemodynamic parameters from the NICOM system could predict post-spinal anesthesia hypotension.
Can baseline hemodynamic parameters obtained via non-invasive cardiac output monitoring predict post-spinal anesthesia hypotension in parturients undergoing cesarean section?
Can baseline hemodynamic parameters obtained via non-invasive cardiac output monitoring predict post-spinal anesthesia hypotension in parturients undergoing cesarean section?
Baseline cardiac output index obtained via non-invasive monitoring may help predict post-spinal anesthesia hypotension in parturients undergoing cesarean section.
May aid hypotension risk stratification in cesarean patients; hypothesis-generating and requires prospective validation before practice change.
The administration of high‑level spinal anesthesia for cesarean section may lead to significant hemodynamic changes. Bioreactance‑based non‑invasive cardiac output monitoring (NICOM™) provides an accurate monitoring system for parturients under spinal anesthesia. The present study hypothesized that baseline hemodynamic parameters obtained via the NICOM™ system could serve as predictive indicators for post‑spinal anesthesia hypotension. Therefore, 80 full‑term parturients with singleton pregnancies who underwent scheduled cesarean section were enrolled and allocated to either a supine position group or a 15˚ left tilt group. All parturients received standard pre‑hydration with 750 ml of 0.9% saline. Baseline cardiac output index (CI), total peripheral resistance index (TPRI) and stroke volume (SV) were recorded using the NICOM™ system. Subsequently, spinal anesthesia with 2.4 ml of 0.5% hyperbaric bupivacaine, 10 µg of fentanyl and 0.2 mg of morphine was administered. Receiver operating characteristic (ROC) curves and multivariate logistic regression were used to analyze the data. A total of 40 parturients (51.9%) developed hypotension. The areas under the ROC curves were 0.666, 0.594 and 0.622 for the CI, TPRI and SV, respectively. The optimal cut‑off value of the CI in predicting hypotension was 3.68 l/min/m2 (ROC, sensitivity=85.0%, specificity=48.6%). Furthermore, CI was considered as an independent factor for post‑spinal anesthesia hypotension. In conclusion, the baseline CI obtained via the bioreactance‑based NICOM™ system may serve as a predictor of post‑spinal anesthesia hypotension in parturients regardless of patient position.
No takes yet. Share an insight, caveat, or question.
Yeh et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: