This paper investigates a linear electromagnetic launcher with tubular transverse flux permanent-magnet linear machine (TFPMLM). Special focus is given on its cogging force characteristic, including the theoretical analysis and computer-aided simulation. Both 3-D and equivalent 2-D finite-element analyses are performed to calculate the cogging force, and the results are compared. It is shown that the proposed 3-D to 2-D equivalence can predict the cogging force of the tubular TFPMLM in an accurate and fast way.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2010) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: