The resistivity responses of layered compound TiS2 to oxygen and nitrogen gases were measured around room temperature. The resistivity showed a selective and reversible response to oxygen. This may be due to the fact that oxygen intercalates into van der Waals gaps in the layered structure of TiS2. The resistivity showed an increment of 1% oxygen partial pressure in 10 min at 50°C. From the comparison with a commercial oxygen gas sensor, it was shown to operate at a lower temperature with the response time as short as the commercial one.
No takes yet. Share an insight, caveat, or question.
Kishiro et al. (1994) studied this question.