Two variations of a continuous-time instantaneous companding filter were integrated in a 25 GHz bipolar process. Their -3-dB frequencies are tunable in the ranges of 1-30 and 30-100 MHz. The DC gains are controllable up to 10 dB. The measured dynamic ranges for a 1% total harmonic distortion are 62.5 and 50 dB, for the 30 and 100 MHz filters, respectively. At maximum cutoff frequencies, the filters dissipate 6.5 mW from a 1.2 V supply.
No takes yet. Share an insight, caveat, or question.
El-Gamal et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: