The utilization of the operational amplifier pole in the design leads to filters with satisfactory high-frequency performance. The approach reduces the number of capacitors required leading to circuits suitable for integration. Circuit arrangements for a bandpass filter and a second-order Butterworth low-pass filter have been suggested using only resistors and two operational amplifiers. The circuits have low parameter sensitivities.
No takes yet. Share an insight, caveat, or question.
S. Srinivasan (1974) studied this question.