Key points are not available for this paper at this time.
Design
Editorial
Answers are grounded in this paper and cite their sources.
This editorial highlights significant theoretical and model-based inconsistencies in the reservoir wave paradigm, suggesting it may not accurately reflect arterial hemodynamics.
Systemic pressure depends on the function of the cardiac pump and on its load – the arterial system. Hypertension, a predictor of cardiovascular events, also is the result of changes of arterial load and heart. To better understand the contribution of the arterial tree to hypertension, a number of analysis methods have been proposed, the most recent of them being the so-called reservoir wave paradigm (RWP) [1]. The RWP is an approach in which the arterial system is considered to be a reservoir for blood storage, resulting in a ‘reservoir pressure’, on the one hand, and a system of elastic tubes with traveling pressure (and flow) waves, resulting in ‘excess pressure’ on the other hand. Measured aortic pressure is the sum of these two pressures. In the present study by Segers et al.[2], one of the major assumptions of the RWP is investigated. This assumption states that the change in reservoir pressure is proportional to the difference between aortic inflow and outflow (i.e. aortic volume changes) [1,3]. Since in-vivo aortic volume is difficult to measure and thus the relation with reservoir pressure virtually impossible to validate, Segers et al.[2] used a model of the arterial tree to test reservoir pressure–volume proportionality. The model used is quite complex, but is a good representation of reality, and therefore the details of the model are here not very important to accept the outcome. The model shows that, especially when reflections in the arterial system are increased (aortic coarctation or stent), the reservoir pressure–volume proportionality does not hold. This finding casts serious doubts on the validity of the RWP. To obtain information about the arterial changes contributing to hypertension, a number of methods to quantify the arterial load have been proposed. The most often used approaches are wave analysis and separation method [4], and the Windkessel model [5]. The third most recent approach, the so-called RWP, under scrutiny here, can be seen as a synthesis of Windkessel (reservoir) behavior and wave behavior of the arterial system. The arterial system is a (large) number of elastic tubes with waves set up by the pulsatile heart that travel and are reflected at numerous locations. Since pressure and flow waves are present, it seems logical to explain the changes in pressure and flow in health and hypertension on the basis of waves. This has led to waveform and wave separation analysis, that is, pressure and flow waves are separated in their forward and backward components [4]. For instance, in aging, the waves that are reflected at many locations – the backward waves – in the arterial tree return somewhat earlier, and possibly with larger amplitudes at the heart since wave speed [pulse wave velocity (PWV)] increases and reflections may be augmented when the arteries are stiffer. In the Windkessel approach, wave travel is not considered, but the system is studied at its entrance without assuming waves. This means that only overall information on the whole arterial system is obtained, and wave travel is not incorporated. The Frank Windkessel, consisting of total arterial systemic compliance (C) and (micro)vascular resistance (SVR), was later extended with a third parameter [6] – aortic characteristic impedance (Zc, proximal aortic wave speed divided by aortic area). Using this model, measured pressure and flow in the ascending aorta allow estimation of these functional parameters [7]. It may be seen from Fig. 1 that adding the pressure calculated from flow and characteristic impedance (flow times Zc) to the pressure predicted by Frank's Windkessel results in an accurate prediction of measured pressure. In old-age hypertension, large artery stiffness was shown to be the main determinant of the increase in systolic and (small) decrease in diastolic pressure after 50 years of age [7]. However, Segers et al.[2] also showed that with aortic coarctation and stenting, this model falls short.FIGURE 1: Relations between pressures. Measured pressure and flow (black) can be separated into their forward and backward pressure (green) components using (classical) wave separation. Reservoir pressure (blue) equals two times the backward pressure wave. Excess pressure (red) is the difference between measured and reservoir pressure and also equals characteristic impedance times flow. WK, Windkessel.The reservoir–wave paradigm was proposed by the Tyberg group on the basis of (presumed) inconsistencies of the two above-mentioned models [1,8]. A major argument against the classical wave separation approach was that in ventricular diastasis (diastole after isovolumic relaxation), flow is zero, and thus no waves are present in the arterial system. Consequently, they concluded that a Windkessel must hold in diastasis. However, opponents supporting the wave separation approach argued that with closed aortic valves, forward and reflected waves cancel (‘closed-end tube’). In the RWP model, pressure is assumed to result from two phenomena. The arterial load is considered to be a blood reservoir – a compliance C – where ejected blood volume (stroke volume) is stored and the stored blood is discharged through the peripheral vessels (arterial resistance R). This is essentially the so-called Frank or two-element Windkessel (Fig. 1). The reservoir pressure is assumed proportional with (thoracic) aortic volume. The difference between predicted and measured pressures, represented by the colored area of Fig. 1, is called the ‘excess pressure’ which is considered to contain wave phenomena and can be separated in forward and backward waves, according to wave intensity analysis [8,9]. The combination of the effects of the reservoir (arterial compliance and vascular resistance) and wave behavior of excess pressure gives the RWP its name. Davies et al.[10] showed that reservoir pressure does, but backward pressure derived from excess pressure does not, relate with age, and that excess pressure predicts cardiovascular events [11]. Several researchers published papers, however, showing strong limitations of the RWP. Mynard and Smolich [12] and Mynard [13] showed that the reservoir parameters are influenced by wave propagation effects, that is, the reservoir pressure has wave properties. On the other hand, Tyberg et al.[14] argued that backward pressure appears to run forward not backward, which would contradict wave theory. However, their reasoning was based on the assumption that the arterial system contains a single, not multiple, reflection sites [15]. Mynard and Smolich [16] also reported that some waves obtained by wave separation of the excess pressure were underestimated and others were overestimated and can produce erroneous information about vascular properties. In other words, the separation of the aortic pressure wave into reservoir phenomena and waves seems incorrect. Recently, Mynard and Smolich [17] showed that the zero flow in diastole can be accounted for by the classical wave separation technique proving that the RWP is not necessary in the explanation. It has been shown by association that the reservoir pressure equals twice the reflected pressure wave obtained by classical wave separation [18]. This relation can also be derived mathematically. Since the backward pressure is a traveling wave, the assumption of the paradigm, namely that the reservoir pressure is not a wave, is in itself conflicting. In the present study, Segers et al.[2] show other inconsistencies of the RWP. The major one is that the reservoir pressure is not related to thoracic aortic volume as assumed by the RWP [1]. Segers et al.[2] also showed that the reservoir pressure volume relations of the aorta exhibit loop-like behavior over the cardiac cycle and that this (counter clockwise) loop implies the generation of energy, which is an impossible condition. Moreover, the excess pressure is overestimated and the reservoir pressure underestimated in the case of coarctation [2]. All in all, some studies have used the RWP [10,11] to explain arterial changes taking place in hypertension, whereas several other studies have queried the value of the RWP. It should, however, be mentioned that both Mynard's [12,13,16,17] and Segers’ [2] critiques are to a large extent based on model approaches. The model-based analysis makes it difficult for the general reader to grasp this work in detail, and, as in all models, has certain limitations. Therefore, comparison of the arterial information obtainable form the RWP, the Windkessel and classical wave travel analyses is eagerly awaited. ACKNOWLEDGEMENTS Funding: none.
No takes yet. Share an insight, caveat, or question.
Westerhof et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: