An electronic model is described which features a multiple input compartmental system analogous to a dendritic net and a simulated action potential. The inputs to the model are rectangular voltage pulses which initiate excitatory and/or inhibitory conductance changes in the dendritic compartments; the outputs are the simulated action potential and a simultaneous rectangular voltage pulse. In addition, the membrane potential at each compartment and the depolarizing and hyperpolarizing conductances can be conveniently monitored.
No takes yet. Share an insight, caveat, or question.
Pottala et al. (1973) studied this question.