Answers are grounded in this paper and cite their sources.
In order to arrive at ion and electron concentrations, temperatures, etc., from Langmuir probe data, one uses the Mott-Smith-Langmuir equations and, in most cases, a rather arbitrary assumption of a fixed value of sheath thickness. This approach has obvious limitations since the sheath's properties are not fixed but must depend on the potential and size of the probe; sheath thickness is clearly zero at zero potential. Walker has treated the nonlinear screening problem for the case of spherical bodies in collisionless monoenergetic and Maxwellian plasmas. The calculations are elaborate, but results can be displayed graphically or given by approximate analytic expressions. We have extracted from these a relationship for the sheath thickness s in terms of the probe's radius ρ and potential ψ, for use in the Mott-Smith-Langmuir equations: s = 0.83 ψ½ ρ⅓; where s, ρ are measured in Debye lengths ψ in terms of kT. For the case of cylindrical symmetry, s = 1.66 ψ¾, and depends only weakly on ρ.
No takes yet. Share an insight, caveat, or question.
Bettinger et al. (1965) studied this question.