Stent implantation for homograft stenosis in tetralogy of Fallot can be complicated by compression of a single right coronary artery system.
Alerts to coronary compression risk in TOF homograft stenting; leaves open optimal pre-procedural imaging protocols.
Successful stent implantation for conduit stenosis has been described; however, this procedure may be complicated by compression of adjacent structures during expansion. We report on a rare case of a single right coronary artery system complicating stent implantation for relief of homograft stenosis in tetralogy of Fallot. Cathet. Cardiovasc. Diagn. 42:405–407, 1997.