Answers are grounded in this paper and cite their sources.
Simulation study demonstrates that static wake steering increases power output across floating wind farms, highlighting trade-offs with component-specific structural fatigue loads.
Static wake steering can increase wind-farm power production, but its application to floating offshore wind farms requires assessment of the coupled wake, platform, structural, and station-keeping response. This study evaluates whether power-maximizing static yaw setpoints identified using the steady, control-oriented FLORIS model retain their benefit when transferred without re-optimization to a coupled FAST.Farm floating wind-farm model. The reference farm comprises four IEA Wind 15 MW turbines mounted on VolturnUS-S semi-submersible platforms. Greedy and static wake-steering operations are compared at three below-rated wind speeds, three sea states, and five matched turbulent-inflow realizations, resulting in 90 farm-level FAST.Farm simulations. Wake behavior is characterized through wake-center deflection, meandering, and velocity-deficit profiles, while turbine and mooring fatigue responses are evaluated using paired damage-equivalent-load statistics. Static wake steering increases mean farm power under all nine investigated wind–wave conditions. The gains are approximately 5.1–5.2% at 7ms−1, 5.0–5.1% at 8ms−1, and 4.0–4.2% at 9ms−1, with all paired 95% confidence intervals remaining above zero. The gain results from a power redistribution in which the intentionally yawed upstream turbine incurs a local loss that is exceeded by the combined recovery of the downstream turbines. The fatigue response is strongly component- and turbine-dependent. The paired farm-mean blade-root DEL decreases by 0.82–2.24%, whereas the tower-base DEL increases by 0.76–2.78%, and the FairTen1 response generally increases by 0.88–2.92%. The farm-mean yaw-bearing response is mixed, ranging from a 1.15% reduction to a 4.32% increase. Turbine-level analysis reveals larger localized penalties, reaching approximately 10.4% for the yaw-bearing DEL and 12.8% for FairTen1. Spectral analysis associates the yaw-bearing response with yaw-induced aerodynamic and structural excitation, while the tower-base response is strongly influenced by low-frequency wave–platform dynamics. A complementary FLORIS sensitivity analysis demonstrates that the optimized aerodynamic benefit depends strongly on wind direction, spacing, wind speed, and turbulence intensity. For a Tampen-derived 11-turbine layout, resource weighting over the modeled 4–13ms−1 interval produces an annual energy-contribution increase of 3.653GWhyear−1, or 0.921%. These results provide numerical evidence that static wake steering can retain a positive power benefit in a coupled floating wind-farm environment, but controller assessment must include turbine- and component-specific dynamic loads rather than farm power alone.
No takes yet. Share an insight, caveat, or question.
Ebrahimi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: