Key result
ACS NSQIP morbidity prediction proves accurate overall but miscalibrates risk by operative time.
Why the study?
General surgical risk models support perioperative counselling, but acceptable overall calibration may conceal clinically important error in microsurgical reconstruction.
Observational (n=20,604)
Yes
Generalized ACS NSQIP morbidity prediction models systematically miscalibrate risk across operative time in microsurgical reconstruction, overestimating risk in shorter operations and underestimating it in longer ones.
Answers are grounded in this paper and cite their sources.
NSQIP models may miscalibrate morbidity risk by operative time in microsurgery; leaves open need for specialty-specific validation before routine use.
Background: General surgical risk models support perioperative counselling, but acceptable overall calibration may conceal clinically important error. We evaluated generalized American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) predictions after microsurgical reconstruction and tested whether morbidity calibration varied across operative time. Methods: Adult ACS NSQIP cases from 2014–2023 were analyzed. Plastic-surgery-service cases meeting exact principal Current Procedural Terminology (CPT) or principal-procedure-text criteria formed the primary cohort. Performance was assessed using observed-to-expected (O:E) ratios, discrimination, and calibration measures. Operative-time calibration was examined by quartiles, deciles, and continuous spline models. Sensitivity analyses used exact principal CPT codes alone and excluded cases with a known morbidity component or reoperation on postoperative day 0 or 1. Results: Among 20,604 microsurgery cases, observed and predicted morbidity were similar overall (12.52% vs. 12.79%; O:E, 0.98; 95% confidence interval [CI], 0.94–1.02), although discrimination was modest (area under the receiver operating characteristic curve, 0.639; 95% CI, 0.627–0.651). Mortality was uncommon (21 deaths; O:E, 0.81; 95% CI, 0.50–1.24). Aggregate calibration concealed a graded reversal across operative time. Morbidity was overpredicted in the shortest quartile (8.66% observed vs. 12.87% predicted; O:E, 0.67; 95% CI, 0.61–0.74) and underpredicted in the longest quartile (16.94% vs. 12.96%; O:E, 1.31; 95% CI, 1.22–1.40). The prespecified linear interaction was nonsignificant (P = 0.183), whereas flexible continuous analyses demonstrated calibration variation before and after global recalibration (both P < 0.001). Findings persisted in both sensitivity analyses. Conclusions: Generalized ACS NSQIP morbidity prediction was accurate in aggregate but systematically miscalibrated across the operative-time gradient, overestimating risk in shorter operations and underestimating it in longer operations. Realized operative time should be interpreted as a postoperative marker of incompletely captured procedural complexity and intraoperative course, not as a causal exposure or preoperative predictor.
No takes yet. Share an insight, caveat, or question.
Sekhon et al. (2026) conducted an observational in microsurgical reconstruction (n=20,604). Operative time was evaluated on morbidity (O:E 0.98, 95% CI 0.94-1.02). ACS NSQIP morbidity prediction was accurate overall but miscalibrated across operative time, overestimating risk in shorter and underestimating in longer operations.