Key result
Patient Safety Scale for Home Peritoneal Dialysis demonstrates excellent internal consistency and test-retest reliability.
Why the study?
Home-based peritoneal dialysis introduces unique patient safety risks, but there is no validated tool to assess patient safety in home settings.
Cross-Sectional (n=600)
Yes
The newly developed Patient Safety Scale for Home Peritoneal Dialysis is a valid and reliable tool for assessing environmental, behavioral, and procedural safety risks in home dialysis patients.
New PD safety scale may aid home risk assessment; leaves open prospective validation before clinical use.
BACKGROUND: Home-based peritoneal dialysis treatment offers greater autonomy and flexibility. However, it also introduces unique patient safety risks. Despite these risks, there is no validated tool to assess patient safety in home settings. OBJECTIVES: To develop and validate a scale to assess environmental, behavioral, and procedural safety risks in peritoneal dialysis (PD). METHODS: This study was conducted with 600 patients across eight hospitals. Item generation was informed by literature review, clinical guidelines, existing instruments, and expert consultation, resulting in an initial 50-item pool. Content validity was established through expert opinions. The final analytic sample was randomly divided into two independent subsamples: exploratory factor analysis was conducted with Sample I (n = 300), and confirmatory factor analysis was conducted with Sample II (n = 300). Internal consistency, test-retest reliability, and convergent and discriminant validity were evaluated. RESULTS: /df = 2.487; CFI = 0.968; RMSEA = 0.035). The scale demonstrated excellent internal consistency (α = 0.939) and strong test-retest reliability (ICC = 0.938). Convergent and discriminant validity criteria were satisfied. CONCLUSION: The scale is a valid and reliable instrument for assessing patient safety in peritoneal dialysis. It addresses critical domains aligned with international safety frameworks and can support clinicians in identifying safety risks, guiding interventions, and improving outcomes in home dialysis.
No takes yet. Share an insight, caveat, or question.
AYDIN et al. (2026) conducted a cross-sectional in Home peritoneal dialysis (n=600). Patient Safety Scale for Home Peritoneal Dialysis (PD-PSS) was evaluated on Scale validity and reliability. The Patient Safety Scale for Home Peritoneal Dialysis demonstrated excellent internal consistency (α = 0.939) and strong test-retest reliability (ICC = 0.938).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: