Key result
Spleen stiffness measurement strongly detects esophageal varices, enhanced by sequential ANTICIPATE-NASH scoring in low-stiffness patients.
Why the study?
The performance of spleen stiffness measurement in real-world settings with diverse etiologies remained unclear.
Does a sequential strategy integrating 100-Hz spleen stiffness measurement and the ANTICIPATE-NASH model improve the detection of esophageal varices in patients with advanced chronic liver disease?
Cross-Sectional (n=91)
Double-blind (endoscopists blinded to elastography, operators blinded to endoscopy)
No
Does a sequential strategy integrating 100-Hz spleen stiffness measurement and the ANTICIPATE-NASH model improve the detection of esophageal varices in patients with advanced chronic liver disease?
Effect estimate: AUROC 0.81 (95% CI 0.72-0.91)
A sequential diagnostic strategy using spleen stiffness measurement and the ANTICIPATE-NASH model enhances the noninvasive detection of esophageal varices in patients with advanced chronic liver disease.
Sequential SSM-ANTICIPATE-NASH may refine EV detection in ACLD; leaves open need for multicenter validation before adoption.
Spleen stiffness measurement (SSM) is an established noninvasive marker of portal hypertension. However, its performance in real-world settings with diverse etiologies remains unclear. This study determined whether a sequential strategy integrating 100-Hz SSM and the BMI-adjusted ANTICIPATE-NASH model improves the detection of esophageal varices (EV) in patients with advanced chronic liver disease (ACLD). This diagnostic accuracy study was conducted at Vajira Hospital, Thailand, during August 2025 to Jaunary 2026. Ninety-one patients with ACLD underwent vibration-controlled transient elastography (100-Hz SSM and liver stiffness measurement [LSM]) followed by endoscopy within 3 months. Diagnostic performance was assessed with subgroup analyses performed according to SSM strata and nonselective beta-blocker (NSBB) exposure. EV were present in 35 patients (38.5%), including 9 patients (25.7%) with high-risk EV. SSM demonstrated the strongest overall discriminative ability (AUROC 0.81), with an optimal cutoff of ≥ 40.6 kilopascals yielding 77.1% sensitivity and 76.8% specificity. LSM and the ANTICIPATE-NASH score showed modest performance (AUROC 0.70). Performance varied across SSM strata. In patients with SSM < 21 kPa, ANTICIPATE-NASH showed a high discrimination (AUROC 0.86). In patients not receiving NSBBs, the incremental value of ANTICIPATE-NASH persisted in the low-SSM subgroup. Sequential SSM with ANTICIPATE-NASH, enhances diagnostic precision for detecting varices, particularly in individuals with lower spleen stiffness.
No takes yet. Share an insight, caveat, or question.
Krairaweengarmwijitr et al. (2026) conducted a cross-sectional in Advanced chronic liver disease (n=91). 100-Hz spleen stiffness measurement (SSM) and ANTICIPATE-NASH score vs. Endoscopy (gold standard) was evaluated on Diagnostic accuracy (AUROC) for detecting esophageal varices (AUROC 0.81, 95% CI 0.72-0.91). Spleen stiffness measurement demonstrated strong discriminative ability for detecting esophageal varices (AUROC 0.81), and sequential use of the ANTICIPATE-NASH score improved detection in patients with low spleen stiffness.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: