Answers are grounded in this paper and cite their sources.
Distal coronary stent deformation is an uncommon but challenging complication of percutaneous coronary intervention. We report the case of a patient with distal deformation of a previously implanted right coronary artery stent caused by entrapment and forceful withdrawal of a jailed guidewire. Intravascular ultrasound (IVUS) confirmed stent-lumen recrossing and severe distal stent underexpansion. Sequential balloon dilatation using progressively larger semicompliant balloons followed by noncompliant balloon optimization restored both stent expansion and longitudinal geometry, avoiding the need for additional stent implantation. Based on this experience, we propose a practical treatment algorithm in which the pattern of guidewire recrossing guides subsequent management. This case highlights the value of IVUS-guided assessment and provides a practical approach to the management of distal coronary stent deformation.
No takes yet. Share an insight, caveat, or question.
Garcia et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: