Key result
Transaortic mitral pannus removal safely reduces discharge mean prosthetic gradients by ~2 mmHg.
Why the study?
The safety and feasibility of transaortic mitral pannus removal during repeat cardiac surgery for patients with mechanical mitral valves was not well established.
Does transaortic mitral pannus removal improve the mitral transprosthetic mean pressure gradient in patients with a mechanical mitral valve undergoing repeat cardiac surgery?
Cohort (n=34)
No
Does transaortic mitral pannus removal improve the mitral transprosthetic mean pressure gradient in patients with a mechanical mitral valve undergoing repeat cardiac surgery?
Transaortic mitral pannus removal is a safe and feasible technique that significantly improves high transprosthetic pressure gradients during repeat surgery, potentially avoiding the high risks associated with repeat mitral valve replacement.
Answers are grounded in this paper and cite their sources.
May support gradient reduction during reoperative mitral surgery; leaves open randomized confirmation of durability versus replacement.
BACKGROUND This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (P<0.001). No mechanical valve malfunction was apparent on last echocardiography. CONCLUSIONS TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.
No takes yet. Share an insight, caveat, or question.
Park et al. (2017) conducted a cohort in Rheumatic heart disease with mechanical mitral valve requiring repeat cardiac surgery (n=34). Transaortic mitral pannus removal was evaluated on Mitral transprosthetic mean pressure gradient (TMPG) at discharge in patients with preoperative TMPG ≥5 mmHg (decreased from 6.46±1.1 to 4.37±1.17 mmHg, p=<0.001). Transaortic mitral pannus removal safely and decreased the mitral transprosthetic mean pressure gradient from 6.46 to 4.37 mmHg at discharge in patients with a preoperative gradient of ≥5 mmHg.
Synapse has enriched 10 related papers. Consider them for comparative context: