The population-statistical description of a linear optical amplifier, extended to include both a resonant optical cavity and explicit input and output photon fluxes, is shown to yield three useful noise relationships. Despite the treatment's plainly particulate character, it provides an expression for the variance of the time-integrated output-photon-detection process in which terms associated with interferometrically generated beat noise are prominent. For systems whose photodetector electrical bandwidth B is much smaller than the amplifier's optical bandwidth Delta v, as is almost invariably the case for semiconductor amplifiers in lightwave-communication systems, the time-integrated photocurrent variance can be written in a simple, physically intuitive form. Two quotients are of central importance: ( Delta nu /B) and the ratio (/) of mean amplified-signal power to mean amplified-spontaneous-emission power. In the usual case of interest for optical amplifiers in communication systems where>>, the signal-to-noise ratio of the integrated photocurrent, on which the error probability in an on-off-keyed system depends, is approximately=1/2( Delta v/B) ((n/sub S/)/(n/sub ASE/)).>