Key result
Transvenous artificial pacemaker implantation in dogs resulted in 100% survival at 48 hours, a 13% major complication rate, and a mean survival time of 2.2 years for those who died.
Why the study?
What are the indications, complications, and survival outcomes of transvenous pacemaker implantation in dogs?
Observational (n=105)
No
What are the indications, complications, and survival outcomes of transvenous pacemaker implantation in dogs?
Transvenous pacemaker implantation in dogs has a high success rate and a comparatively low complication rate when performed at an experienced single institution.
Supports use at experienced centers; leaves generalizability and long-term outcomes open for multicenter study.
We reviewed the indications for age and breeds of dogs who received transvenous endocardial artificial pacemaker (AP) implantation (n = 105) and complications and survival thereafter at a single institution over a 6-year period. A third-degree atrioventricular (AV) block (59%) and sick sinus syndrome (SSS; 27%) were the most common indications, along with a high-grade second-degree AV block (9%) and atrial standstill (5%). The most common breeds identified were Labrador Retriever (n = 16; 11 with a third-degree AV block), American Cocker Spaniel (n = 14; 10 with SSS), and Miniature Schnauzer (n = 13; all with SSS). Common presenting complaints were syncope (n = 66) and exercise intolerance or lethargy (n = 25). Half of the dogs (n = 52) had a history of acute onset of clinical signs (<2 weeks). Mean survival time for the 60 dogs who died during the study period was 2.2 years (range, 0.1-5.8 years). Major complications occurred in 13% of dogs and included lead displacement (n = 7), sensing problems that led to syncope (n = 3), infection at the pacemaker site (n = 1), bleeding (n = 1), and ventricular fibrillation during implantation (n = 1; successfully defibrillated). Minor complications occurred in 11 dogs (11%). The success rate of transvenous AP implantation was comparatively high (all dogs survived the first 48 hours), and the complication rate was comparatively low when compared with a previous multicenter study, most likely because of how commonly the procedure was performed and supervisory experience.
No takes yet. Share an insight, caveat, or question.
Wess et al. (2006) conducted an observational in Bradyarrhythmias requiring pacemaker (e.g., third-degree AV block, sick sinus syndrome) (n=105). Transvenous endocardial artificial pacemaker implantation was evaluated on Survival and complications. Transvenous artificial pacemaker implantation in dogs resulted in 100% survival at 48 hours, a 13% major complication rate, and a mean survival time of 2.2 years for those who died.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: