Answers are grounded in this paper and cite their sources.
A simple method to precisely measure the trench depth of VLSI DRAM's capacitor cells is presented. The measurement system uses a Michelson interferometer and a white light source. The trench depth is transformed into the optical path difference between the central peak and one of sideband peaks produced during one-way scan of a mirror in a Michelson interferometer. The measurement error was within±0.2 for trench depths of2-5 . The multimode fiber used in the system facilitates wafer setup so that the system can be introduced into an in-process measurement system.
No takes yet. Share an insight, caveat, or question.
Takada et al. (1987) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: