BACKGROUND AND PURPOSE: The Emory Functional Ambulation Profile (E-FAP) measures time to walk in different environments and accounts for use of assistive devices. This study assessed the reliability and validity of walking time measurements using these components. SUBJECTS: Twenty-eight subjects who had strokes and 28 subjects without impairment were recruited. METHODS: The E-FAP, Berg Balance Test, Functional Reach Test, and Timed 10-Meter Walk Test were administered in random order during a single data collection session. RESULTS: Interrater reliability for the total E-FAP was > or = .997. Subjects without impairment performed better on all 4 tests than did subjects who had strokes. Increased times on the E-FAP correlated with poor performance on the Berg Balance Test and slow gait speeds on the Timed 10-Meter Walk Test in the subjects who had strokes. The E-FAP scores and the Functional Reach Test scores were not correlated. CONCLUSION AND DISCUSSION: The E-FAP can be administered easily and inexpensively. Because the E-FAP scores differentiated subject groups and correlated with known measures of function, the E-FAP may be a clinically useful measure of ambulation.
No takes yet. Share an insight, caveat, or question.
Wolf et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: