BACKGROUND: The use of permanent intravenous access devices for chemotherapy administration has become a common practice in clinical oncology. Therefore, awareness of potential complications is important. The authors previously reported the use of high dose 5-fluorouracil (5-FU) (2600 mg/m2) and leucovorin (500 mg/m2) as a weekly 24-hour infusion for patients with colorectal carcinoma. In this report, a new complication of permanent indwelling catheters with high dose 5-fluorouracil (2600 mg/m2) and leucovorin (500 mg/m2) as a weekly 24-hour infusion for colorectal carcinoma is described. METHODS: Twenty-two patients in the previous Phase II trial on weekly high dose 5-FU and leucovorin were included in this study. All patients had either a single-lumen Port-o-cath (Pharmacia Deltec, St. Paul, MN) or Hickman catheter (Travenol Laboratories, Deerfield, IL). Occluded catheters were explanted, and the material found in their lumen was analyzed using infrared spectroscopy. RESULTS: Eleven of 22 patients had catheter blockage, and calcium carbonate formation (Calcite 100%) was identified within these catheters. CONCLUSION: Calcite formation causing catheter occlusion is a new and important complication resulting from using intravenous access devices for chemotherapy administration. Oncologists should be alerted to this phenomenon when high dose 5-FU and leucovorin are administered for 24 hours by continuous infusion using a single-port port-o-cath.