This paper introduces an approach to near time-optimal control for synchronous buck dc–dc converters. The proposed proximate time-optimal digital (PTOD) controller is a combination of a constant-frequency pulsewidth modulation (PWM) controller employing a linear PID compensator close to a reference point, and a linear or nonlinear switching surface controller (SSC) away from the reference, together with smooth transitions between the two. A hybrid capacitor current estimator enables switching surface evaluation and eliminates the need for current sensing. The SSC, which is implemented as a small Verilog HDL module, can be easily added to an existing digital PWM controller to construct the PTOD controller. In steady state, the controller operates exactly the same as a standard constant-frequency PWM controller with a linear PID compensator. Simulation and experimental results are shown for a 6.5 V-to-1.3 V, 10A synchronous buck converter.
No takes yet. Share an insight, caveat, or question.
Yousefzadeh et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: