Key result
A distributed model of the human arterial tree incorporating a baroreflex loop accurately predicted experimental pulse morphology parameters under upper arm cuff pressure.
Why the study?
Does a distributed model of the human arterial tree incorporating a baroreflex loop accurately predict haemodynamic changes due to upper arm cuff pressure?
Does a distributed model of the human arterial tree incorporating a baroreflex loop accurately predict haemodynamic changes due to upper arm cuff pressure?
Answers are grounded in this paper and cite their sources.
A distributed computational model of the human arterial tree that includes a baroreflex loop accurately predicts changes in pulse morphology caused by upper arm cuff pressure.
We propose a distributed model of entire human arterial tree to describe the haemodynamic changes due to pressure applied on the brachial artery. The model (without baroreflex) parameters are positively correlated with measured parameters (maximum systolic slope r = 0.54; maximum diastolic slope r = 0.77; pulse height r = 0.89 when P < 0.05). We calculated correlation coefficient of all parameters with baroreflex system (for maximum systolic slope r = 0.97; for maximum diastolic slope r = 0.93; for pulse height r = 0.99 when P < 0.05). With baroreflex loop in the model, the experimental parameters are accurately predicted.
No takes yet. Share an insight, caveat, or question.
Viswajith et al. (2011) studied this question. Upper arm cuff pressure was evaluated on Correlation of model parameters with measured parameters (maximum systolic slope, maximum diastolic slope, pulse height) (p=<0.05). A distributed model of the human arterial tree incorporating a baroreflex loop accurately predicted experimental pulse morphology parameters under upper arm cuff pressure.