Answers are grounded in this paper and cite their sources.
The time dependences of uv emissions from dense argon and xenon are monitored following low-intensity electron excitation. The uv transitions originate on the lowest 0ᵤ⁺ and 1ᵤ molecular states. For argon the radiative lifetimes are 3.2±{}0.3 {μ}sec (1ᵤ) and 4.20±{}0.13 nsec (0ᵤ⁺), while for xenon they are 96±{}5 and 5.5±{}1.0 nsec. The radiating molecules are formed by three-body destruction of excited atoms; the rate coefficient for argon is (2.8±{}0.3) ×{} 10^-33 cm⁶/sec.
No takes yet. Share an insight, caveat, or question.
Keto et al. (1974) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: