Key result
Robotically-assisted CABG yields ~92% graft patency at 1 year in beating-heart procedures.
Why the study?
What is the feasibility, safety, and graft patency of robotically-assisted beating-heart coronary artery bypass grafting (TECAB and MIDCAB) in patients with single- or double-vessel coronary artery disease?
Cohort (n=56)
No
What is the feasibility, safety, and graft patency of robotically-assisted beating-heart coronary artery bypass grafting (TECAB and MIDCAB) in patients with single- or double-vessel coronary artery disease?
Answers are grounded in this paper and cite their sources.
Beating-heart robotic coronary artery bypass (TECAB and MIDCAB) achieved 92% graft patency at 1 year, but carries a substantial conversion rate (16%) and prolonged operative times that necessitate strict patient and target-vessel selection.
Objectives. Robotic surgery enables to perform coronary surgery totally endoscopically. This report describes our experience using the da Vinci system for coronary artery bypass surgery. Methods. Patients requiring single-or-double vessel revascularization were eligible. The procedure was performed without cardiopulmonary bypass on a beating heart. Results. From April 2004 to May 2008, fifty-six patients were enrolled in the study. Twenty-four patients underwent robotic harvesting of the mammary conduit followed by minimal invasive direct coronary artery bypass (MIDCAB), and twenty-three patients had a totally endoscopic coronary artery bypass (TECAB) grafting. Nine patients (16%) were converted to open techniques. The mean total operating time for TECAB was 372 +/- 104 minutes and for MIDCAB was 220 +/- 69 minutes. Followup was complete for all patients up to one year. There was one hospital death following MIDCAB and two deaths at follow up. Forty-eight patients had an angiogram or CT scan revealing occlusion or anastomotic stenoses (>50%) in 6 patients. Overall permeability was 92%. Conclusions. Robotic surgery can be performed with promising results.
No takes yet. Share an insight, caveat, or question.
Folliguet et al. (2010) conducted a cohort in Single- or double-vessel coronary artery disease referred for surgical revascularization (n=56). Robotically-assisted coronary artery bypass grafting (TECAB or MIDCAB using the da Vinci system on a beating heart) was evaluated on Composite of LIMA-LAD graft patency (permeability) and freedom from target vessel reintervention. Robotically-assisted coronary artery bypass grafting achieved a 92% overall graft permeability rate (48/52 anastomoses) and a 7% target vessel reintervention rate (4/56) at 1-year follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: