This is the authors' abstract. We don't add key points for this paper.
This study evaluated the accuracy of marginal and internal fit between the all-ceramic crowns manufactured by a conventional double-layer computer-aided design/computer-aided manufacturing (CAD/CAM) system and a single-layer system. Ten standardized crowns were fabricated from each of these two systems: conventional double-layer CAD/CAM system (Procera) and a single-layer system (Cerec 3D). The copings and completed crowns were seated on the abutments by a special device that facilitated uniform loading, and the marginal discrepancies were measured. Internal gaps were also measured using a low-viscosity silicone material. Marginal discrepancies of Procera copings were significantly smaller than those of Procera crowns and Cerec 3D crowns (p < 0.05), but Procera crowns and Cerec 3D crowns did not differ significantly from each other (p > 0.05). On internal gaps, Cerec 3D crowns showed significantly larger internal gaps than Procera copings and crowns (p < 0.05). Within the limitations of this study, the single-layer system demonstrated acceptable marginal and internal fit.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2008) studied this question.