Why the study?
Does radionuclide cineangiography during exercise improve the detection of coronary artery disease compared to exercise electrocardiography in patients evaluated for possible CAD?
Does radionuclide cineangiography during exercise improve the detection of coronary artery disease compared to exercise electrocardiography in patients evaluated for possible CAD?
Answers are grounded in this paper and cite their sources.
Radionuclide cineangiography during exercise is highly sensitive, specific, and predictive for detecting coronary artery disease, offering superior diagnostic accuracy compared to exercise electrocardiography.
Noninvasive radionuclide cineangiography permits the assessment of global and regional left ventricular function during intense exercise.To assess the sensitivity of the technique in detecting coronary artery disease, we studied 63 consecutive patients with 50% stenosis of at least one coronary artery.Fiftynine (94%) had regional dysfunction with exercise; 56 (89%) developed lower-than-normal ejection fractions during exercise.When both regional dysfunction and subnormal ejection fractions are considered together, the sensitivity was 95%.Each patient also underwent exercise electrocardiography to either angina or 85% of predicted maximal heart rate.Of the 42 patients who developed angina during exercise electrocardiography, 26 (62%) developed I mm ST-segment depression; four additional patients (10%) had Q waves diagnostic of previous myocardial infarction.In contrast, 39 (93%, p < 0.001) developed regional dysfunction during radionuclide study, and one additional patient developed a subnormal ejection fraction without regional dysfunction.To assess specificity, we studied 21 consecutive patients with chest pain who had normal coronary arteries.None developed regional dysfunction; ejection fraction increased in all to levels within the range previously defined as normal.The predictive accuracy in this symptomatic population was 100%.We conclude that radionuclide cineangiography is highly sensitive (more so than exercise electrocardiography), predictive and specific in detecting patients with coronary artery disease.WE HAVE RECENTLY shown that noninvasive radionuclide cineangiography performed during exer- cise permits the detection of abnormalities in regional left ventricular function and ejection fraction in patients with coronary artery disease (CAD).'In the present study, we assessed the sensitivity and specificity of this technique in detecting CAD, and compared its accuracy with that of exercise electrocar- diography. MethodsWe studied 84 patients (72 men and 12 women, ages 29-70 years) who were admitted to the National Heart, Lung, and Blood Institute for evaluation of possible CAD.All studies were performed at least 48 hours after cessation of propranolol and at least 4 hours after nitroglycerin administration.Each patient
No takes yet. Share an insight, caveat, or question.
Borer et al. (1979) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: