This is the authors' abstract. We don't add key points for this paper.
We are currently under development of a 1 MW-class HTS ship propulsion motor, for which rotating HTS coil made of Bi-2223 tape wire has already been successfully cooled down to 30 K and attained the target performance. There, the electric loss estimation in the HTS tape wire is required under practical operation conditions. The magnetic field angle dependency on IC-B characteristics of Bi-2223 used for the field winding was measured at 40 K. Furthermore, the interlinkage flux density on HTS coils in the horizontal and vertical directions were calculated using three-dimensional magnetic field simulations. It was found that the estimated electric loss of the entire HTS coil using these measured and simulated results was about 9 W at the operating field current of 200 A, which was considerably small compared with 30 W at 215 A, and that the operating field current of 200 A was appropriate and desirable considering the required refrigerator capacity.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Koshiba et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: