Why the study?
Is transfemoral endoluminal repair with a bifurcated graft system safe and successful in patients with abdominal aortic aneurysm?
Is transfemoral endoluminal repair with a bifurcated graft system safe and successful in patients with abdominal aortic aneurysm?
Answers are grounded in this paper and cite their sources.
Transfemoral endoluminal repair with a bifurcated graft system was successful and safe in a small series of selected patients with abdominal aortic aneurysm.
Traditional open repair of abdominal aortic aneurysm has disadvantages. We present our experience of transfemoral endoluminal repair with a bifurcated graft system. 29 patients with aortic aneurysm over 5.5 cm in diameter and 1 with a 3.2 cm aneurysm and bilateral iliac stenosis were assessed; 5 were suitable for the procedure. The operation was successful in all the patients, without haemodynamic compromise or major complications. This technique has the potential to reduce morbidity and mortality from abdominal aortic aneurysm. Further modifications are required to make it applicable to most aneurysms.
No takes yet. Share an insight, caveat, or question.
Yusuf et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: