Design
Editorial
Answers are grounded in this paper and cite their sources.
Real-time 3D transesophageal echocardiography represents a breakthrough technology that fundamentally transforms intraoperative imaging for assessing ventricular function and complex valvular structures.
Two-dimensional transesophageal echocardiography (2D-TEE) is the most frequently used intraoperative imaging technique in cardiac surgery. Since the early days of intraoperative 2D-TEE, its diagnostic value has increased steadily as a consequence of evolving technology and expanding knowledge. In the cardiac operating room, 2D-TEE aids in hemodynamic management, provides timely information to the surgeon without disrupting the surgical workflow, and improves outcome.1–3 Although current guidelines rely on 2D-TEE to diagnose valvular and ischemic heart disease, the concept of 3D echocardiography has long been pursued as a natural evolution of 2D echocardiography.4 Three-dimensional echocardiography has been under development for decades with the first 3D reconstruction of 2D images described in 1974 and the first human 3D-TEE performed in 1992.5,6 Until recently, 3D-TEE was performed using a rotational approach and sequential data acquisition, gated to electrocardiography or respiration.6,7 Subsequent volume rendering and cropping of these reconstructed 3D volume data sets allowed the display of structures of interest. However, these earlier approaches were limited by time-consuming data acquisition and reconstruction, frequent artifacts, and the need for offline processing.8,9 Therefore, reconstructive 3D-TEE remained primarily a research tool that was not incorporated into routine clinical practice. Recent technological advances, however, have revolutionized the field of 3D echocardiography. The most significant of these advances were the introduction of a new class of piezoelectric crystals with remarkably enhanced electromechanical properties, matrix-array transducers using many more imaging elements (>2500), and the subsequent reduction in the size of the transducer footprint such that the technology could be incorporated onto a TEE probe.10–12 With the power of 150 computer boards, the currently available technology uses up to 3000 fully sampled elements for 360° focusing and steering and simultaneous imaging of 2 full-resolution planes without the need to change the scan angle. Furthermore, the system enables live or real-time (RT) volume imaging over a single heartbeat with unlimited planes in all directions resulting in the acquisition and rendering of true RT 3D data. Gated images (full volume) are acquired over multiple heartbeats and are displayed as a loop generated by stitching subvolumes together over consecutive cardiac cycles. RT 3D-TEE usually provides excellent visualization of the mitral valve (MV), the interatrial septum, the left atrial appendage (LAA), pulmonary veins, and the left ventricle (LV), but imaging of the aortic valve (AV) and tricuspid valve (TV) will benefit from further technological improvements.12,13 Although RT 3D-TEE often provides spectacular images, only rigorous scientific evaluation will establish whether these images truly add clinical value to the management of cardiac surgery patients. Furthermore, this emerging technology requires that the echocardiographer attains new sets of skills to acquire and manipulate the 3D data sets. However, given the recent technological advances in 3D echocardiography, the time is right to critically embrace this powerful imaging modality for intraoperative use. A historic quote from the 1834 London Times may illustrate how an ingenious instrument such as the stethoscope was initially underestimated: “… that it will ever come into general use … is extremely doubtful, … because its beneficial application requires much time and gives a good bit of trouble both to the patient and the practitioner … and because (it is) foreign and opposed to all our habits and associations.” In this issue of Anesthesia & Analgesia, Vegas and Meineri14 provide a comprehensive and timely review of the evolution, technology, acquisition, and utility of 3D-TEE. We will build on their contribution by highlighting some of the most important clinical applications of 3D-TEE and discuss key features of the emerging 3D technology. Much like Avatar, the 3D Hollywood sensation that has revolutionized our movie experience, RT 3D echocardiography represents a breakthrough technology that fundamentally transforms intraoperative imaging. ASSESSMENT OF LEFT VENTRICULAR FUNCTION The evaluation of global and regional LV function is an essential part of a routine intraoperative TEE examination. Naturally, the addition of a third dimension overcomes obvious limitations of 2D approaches to LV function because it enables the inclusion of depth and volume. Two-dimensional echocardiography relies on visual estimation and geometric assumptions to approximate LV ejection fraction and volumes, and is limited by foreshortened views and limited reproducibility. Three-dimensional echocardiography, however, provides timely and superior LV mass and function assessment,15,16 and 3D-TEE recently has been shown to offer a more reliable perioperative quantification of LV ejection fraction than 2D-TEE, especially for less-experienced users.17 Importantly, 3D echocardiography along with built-in or freestanding software not only offers reliable measurements of global and regional LV function but also permits “cropping” of the LV full volume to display an infinite number of 2D views.18,19 Cropping provides a complete and dynamic assessment of the LV while sequential examinations (e.g., pre- and postprocedure) can be consistently based on the same imaging plane. Therefore, 3D-TEE may improve the efficiency of a comprehensive intraoperative TEE examination. In addition to conventional midesophageal 4- and 2-chamber and long-axis views, the 3D system also provides up to 16 parallel short-axis slices that can be used for systematic review of segmental wall motion abnormalities. Although the clinical value of 3D evaluation of the LV is already more established for transthoracic echocardiography (TTE), future improvements of this technology and prospective comparisons of 3D-TEE with a “gold standard” such as magnetic resonance imaging will determine whether 3D-TEE can become the new intraoperative standard for accurate and reliable measurement of LV volumes, mass, regional LV function, and dyssynchrony. Other potential future 3D applications include 3D speckle tracking and the use of echocardiographic contrast agents with 3D-TEE, both of which have already been introduced to transthoracic imaging.20–22 ASSESSMENT OF RIGHT VENTRICULAR FUNCTION Because of its complex geometry, the evaluation of the global and regional right ventricular (RV) function is even more challenging than analysis of the LV. All 2D echocardiographic approaches to RV volumes and function are inadequate because they rely on visual estimation and geometric assumptions. Three-dimensional echocardiography may be able to overcome these limitations and has been shown to improve the accuracy and reliability of RV quantification when compared with 2D.23,24 Freestanding software dedicated to RV quantification seems to facilitate the analysis of RV volume and function.25 MITRAL VALVE The MV with its complex saddle-shaped configuration presents one of the most challenging structures to be assessed with 2D-TEE. Two-dimensional TEE imaging of the MV requires mental integration of several views for accurate assessment and is highly dependent on observer experience and expertise. The MV complex with the spatial relationships of the MV to chordae, papillary muscles, and myocardial walls is particularly suited to 3D assessment. There is a growing body of literature demonstrating the added value of 3D versus 2D echocardiography for MV imaging. RT 3D echocardiography with its en face views of the MV allows more accurate identification of the MV anatomy, function, and pathology.8,26–28 Spatial manipulation of the 3D data set enables assessment of the MV in its anatomical or surgical orientation, thereby facilitating the discussion of findings with the surgeon. In addition, the severity of mitral regurgitation (MR) can be more accurately determined using 3D color Doppler echocardiography to determine effective regurgitant orifice areas29 and specific geometric effective regurgitant orifice area shapes representative of different MR pathologies.30,31 Based on these studies, there is reason to believe that current criteria and guidelines for evaluation of the severity of native MV regurgitation and stenosis will be refined based on 3D approaches. A comprehensive MV examination should also include a 3D quantitative assessment of the MV using appropriate software.32 A recently updated version of built-in MV quantification software offers a semiautomated analysis package for improved and more rapid and authentic modeling of the mitral annulus, valve commissures, leaflet coaptation, leaflet topography, and aortic orifice to MV angle. Surgical and interventional procedures on the MV often depend on timely and accurate imaging for both decision making and intraoperative guidance. The ability to use RT 3D-TEE to diagnose complex valvular lesions that combine MV clefts or commissural defects with more prevalent pathology such as a posterior leaflet prolapse may assist surgical decision making because these lesions may be underappreciated in the flaccid, unloaded heart during cardiopulmonary bypass. RT 3D-TEE provides excellent visualization of prosthetic MVs and annuloplasty rings12,33; thus, it does help to identify the precise location of a paravalvular leak.34 RT 3D-TEE has not only been successfully used during open MV procedures, but is also required for guidance during percutaneous mitral edge-to-edge repair and valvuloplasty.35–37 Although currently limited to the cardiac catheterization laboratory, these procedures are ideal candidates for a hybrid operating room, and anesthesiologists should acquire the necessary imaging expertise. AORTIC VALVE AND TRICUSPID VALVE Three-dimensional assessment of the native AV and TV is more challenging than assessment of the MV. Both valves can be optimally visualized only in 18% (AV) and 11% (TV) with RT 3D-TEE, largely because these valves are anterior structures with a longer distance to the transducer, are associated with a less favorable angle of insonation, and have thinner leaflets compared with the MV.12 Whether RT 3D-TEE will improve the accuracy in the assessment of valvular dysfunction similar to what has been described for the MV still needs to be established. RT 3D-TEE may be beneficial during percutaneous AV procedures because it provides superior spatial visualization and facilitates the detection and location of procedure-related complications. Such complications may include malposition or displacement of the AV prosthesis, paravalvular leaks, or the occlusion of the left main coronary artery.38 Early reports using 3D-TTE suggest that assessment of tricuspid regurgitation is feasible in most patients, and that the shape of the vena contracta is more ovoid than that of MR regurgitant jets.39 LEFT ATRIAL APPENDAGE TEE is considered the gold standard imaging modality for detection of LAA thrombi. Despite a relatively high specificity, 2D-TEE imaging may overestimate the incidence of thrombi partly because of the complex morphology of the multilobed LAA,40 a structure that is better suited to 3D assessment. Several case reports regarding RT 3D-TTE or reconstruction 3D-TEE have shown that 3D assessment enables superior imaging of LAA anatomy and function and is particularly helpful in distinguishing thrombi from anatomical variants.41–43 Furthermore, RT 3D-TEE provides excellent visualization of the LAA orifice, which may optimize the guidance for the placement of LAA occlusion devices.44 Successful application of RT 3D-TEE to confirm stable catheter position along the entire length of the ligament of Marshall during left atrial catheter ablation for atrial fibrillation has also been described. RT 3D-TEE could thus potentially enhance lesion delivery during left atrial catheter ablation for atrial fibrillation thereby improving the efficacy and safety of this procedure.45 SUMMARY The evolution from time-consuming and labor-intense off-line reconstruction to RT 3D imaging is one of the most significant developments of the last decade in cardiac ultrasound imaging. RT 3D-TEE allows for enhanced diagnostic accuracy, provides stunning images, and is intuitively educational. Other strengths include the ability to (1) integrate spatial information previously obtained from multiple 2D planes into 1 instantaneous image, (2) accurately quantify cardiac physiology and anatomy, and (3) present complex 3D structures in a more intuitive and efficient fashion so that they can easily be shared with surgeons. Intraoperatively, we believe that 3D-TEE, through RT acquisition, online rendering and cropping, and prompt quantification, will likely revolutionize assessment of complex 3D structures and help to transition this modality into a standard of clinical care (Table 1). In the cardiac catheterization laboratory, RT 3D-TEE is already a requisite for guidance of selected percutaneous catheter-based procedures and will remain as such when the same procedures move to the hybrid operating room. Even perioperatively, where it competes with other noninvasive 3D techniques such as 4D multislice computed tomography and novel 3D magnetic resonance imaging technology, RT 3D-TEE provides valuable clinical information that empowers the echocardiographer with new levels of confidence in diagnosing cardiac pathology. Although RT 3D-TEE is not yet a mature technology, we encourage our colleagues to embrace it and, more importantly, lead its development in the perioperative arena. Just like the stethoscope, RT 3D-TEE is here to stay.
No takes yet. Share an insight, caveat, or question.
Mackensen et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: