Key result
Real-time 3-D triplane echocardiography accurately quantifies RV stroke volume with ~6-mL mean difference vs. 2-DE.
Why the study?
3-D echocardiography can accurately determine RV volume but has not been feasible in clinical practice due to time-consuming off-line processing.
Does real-time 3-D triplane echocardiography accurately quantify right ventricular volume and stroke volume compared to reference standards in porcine hearts and healthy humans?
Cross-Sectional (n=40)
Does real-time 3-D triplane echocardiography accurately quantify right ventricular volume and stroke volume compared to reference standards in porcine hearts and healthy humans?
Real-time 3-D triplane echocardiography provides a rapid and accurate method for quantifying right ventricular volume and stroke volume, showing excellent correlation with reference standards.
Answers are grounded in this paper and cite their sources.
Caution advised before clinical adoption of triplane 3D RV volumetry; leaves open validation in diseased hearts and outcome studies.
AbstractBackgroundPrevious studies have demonstrated that 3‐Dimensional (3‐D) echocardiography can determine right ventricular (RV) volume accurately. However, this technique has not been feasible in everyday clinical practice because of the necessity of time‐consuming off‐line processes.HypothesisA newly developed real‐time 3‐D triplane echocardiography, which acquires 3 apical rotational cross‐sectional images simultaneously, holds the promise to resolve these problems.Methods and ResultsSixteen excised formalin fixed porcine hearts and 24 healthy human subjects underwent real‐time 3‐D triplane echocardiography. In an anatomic in vitro study, the actual volume of RV was obtained by spilling water in the RV cavity into a graduated cylinder for measurement, which served as a reference standard for comparison. For healthy subjects, the RV stroke volume (SV) was measured by triplane echocardiography which was compared with the left ventricular (LV) SV obtained by conventional 2‐Dimensional echocardiography (2‐DE). Excellent correlation and agreement between 3‐D triplane imaging derived RV volume and the actual one for excised porcine hearts were observed (r = 0.979, p < 0.001, mean difference 2.2 mL). In healthy human subjects, good correlation and agreement between 3‐D triplane imaging derived RV SV and LV SV measured by 2‐DE were obtained (r = 0.970, p < 0.001, mean difference 5.9 mL).ConclusionsReal‐time 3‐D triplane echocardiography provides us a new method for rapid and accurate quantification of RV volume. Furthermore, this new method holds the promise for evaluating RV volume and SV in routine clinical practice.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2008) conducted a cross-sectional in Healthy human subjects and excised porcine hearts (n=40). Real-time 3-Dimensional triplane echocardiography vs. Water displacement (in vitro) and conventional 2-Dimensional echocardiography (human subjects) was evaluated on Right ventricular stroke volume (RV SV) (r = 0.970, mean difference 5.9 mL, p=<0.001). Real-time 3-D triplane echocardiography accurately quantified right ventricular stroke volume in healthy subjects, showing excellent correlation with 2-D echocardiography.
Synapse has enriched 10 related papers. Consider them for comparative context: