Answers are grounded in this paper and cite their sources.
Aim: To assess the association between mock-up technique (chairside bis-acryl vs digitally fabricated 3D-printed) and shade-matching protocol (chairside visual vs laboratory-assisted/digital) with patient-initiated esthetic dissatisfaction resulting in refund or retreatment within 12 months of veneer delivery. Settings and Design: Single-center, 1:1 matched case–control study (23 pairs; n = 46) in a private prosthodontic practice. Materials and Methods: Exposures were chairside bis-acryl versus digitally fabricated 3D-printed mock-ups and chairside visual versus laboratory-assisted/digital shade matching. The primary outcome was patient-initiated esthetic dissatisfaction within 12 months resulting in refund or retreatment; refund-only and retreatment-only outcomes were prespecified as exploratory. Statistical Analysis Used: Primary analysis used exact conditional methods for matched pairs (McNemar) with exact 95% confidence intervals; in the presence of separation, the exact lower confidence bound was reported without continuity corrections. A supportive multivariable unconditional logistic regression adjusted for age, sex, exact number of units, arch, and cost tier, and E-values were calculated to assess robustness to unmeasured confounding. Results: Chairside mock-ups and chairside-only shade selection were more frequent in cases than controls. The matched odds ratio (OR) for chairside versus digitally fabricated mock-ups was ∞ (exact lower 95% confidence interval ≥2.51; P = 0.0010), and for chairside versus laboratory-assisted/digital shade matching was 6.00 (95% confidence interval 1.34–55.20; P = 0.0129). In the supportive adjusted model, the ORs were 5.87 (95% confidence interval 1.59–21.66; P = 0.008) for mock-up technique and 4.41 (1.26–15.42; P = 0.021) for shade protocol; corresponding E-values were 11.48, 11.22, and 8.29, respectively. Conclusion: Within the limitations of a retrospective, single-center design and modest sample size, chairside bis-acryl mock-ups and chairside-only shade matching were associated with higher odds of early esthetic dissatisfaction leading to refund or retreatment. Adoption of standardized digital workflows with digitally designed/3D-printed mock-ups and calibrated shade protocols is recommended as a clinical quality-assurance measure to mitigate this risk.
No takes yet. Share an insight, caveat, or question.
Abichandani et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: