This is the authors' abstract. We don't add key points for this paper.
Objective . Many methods for compression and/or de-speckling of 3D optical coherence tomography (OCT) images operate on a slice-by-slice basis and, consequently, ignore spatial relations between the B-scans. Thus, we develop compression ratio (CR)-constrained low tensor train (TT)—and low multilinear (ML) rank approximations of 3D tensors for compression and de-speckling of 3D OCT images. Due to inherent denoising mechanism of low-rank approximation, compressed image is often even of better quality than the raw image it is based on. Approach . We formulate CR-constrained low rank approximations of 3D tensor as parallel non-convex non-smooth optimization problems implemented by alternating direction method of multipliers of unfolded tensors. In contrast to patch- and sparsity-based OCT image compression methods, proposed approach does not require clean images for dictionary learning, enables CR as high as 60:1, and it is fast. In contrast to deep networks based OCT image compression, proposed approach is training free and does not require any supervised data pre-processing. Main results . Proposed methodology is evaluated on twenty four images of a retina acquired on Topcon 3D OCT-1000 scanner, and twenty images of a retina acquired on Big Vision BV1000 3D OCT scanner. For the first dataset, statistical significance analysis shows that for CR ≤ 35, all low ML rank approximations and Schatten-0 ( S 0 ) norm constrained low TT rank approximation can be useful for machine learning-based diagnostics by using segmented retina layers. Also for CR ≤ 35, S 0 -constrained ML rank approximation and S 0 -constrained low TT rank approximation can be useful for visual inspection-based diagnostics. For the second dataset, statistical significance analysis shows that for CR ≤ 60 all low ML rank approximations as well as S 0 and S 1/2 low TT ranks approximations can be useful for machine learning-based diagnostics by using segmented retina layers. Also, for CR ≤ 60, low ML rank approximations constrained with S p , p ∊ {0, 1/2, 2/3} and one surrogate of S 0 can be useful for visual inspection-based diagnostics. That is also true for low TT rank approximations constrained with S p , p ∊ {0, 1/2, 2/3} for CR ≤ 20. Significance . Studies conducted on datasets acquired by two different types of scanners confirmed capabilities of proposed framework that, for a wide range of CRs, yields de-speckled 3D OCT images suitable for clinical data archiving and remote consultation, for visual inspection-based diagnosis and for machine learning-based diagnosis by using segmented retina layers.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Kopriva et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: