Because of the current strong emphasis on low sidelobe antennas, the effects of measurement distance in distorting patterns are reexamined. Previous calculations have used obsolete or suboptimum aperture distributions. The Taylorn̄linear distribution is a versatile highly efficient and robust optimum distribution; its use here allows a single curve of sidelobe measurement error versus measurement distance (normalized to far field distance2D²/λ) for a given sidelobe level. The calculations give data from a uniform distribution to a 60 dB Taylor. For example, the first sidelobe of a 40 dB Taylor pattern is in error 1 dB at a distance of6 D²/λ.
No takes yet. Share an insight, caveat, or question.
R.C. Hansen (1984) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: