Why the study?
Despite guideline recommendations for troponin monitoring during immune checkpoint inhibitor therapy, limited data exist on its predictive significance for cardiovascular complications.
Does a follow-up high-sensitivity troponin I > 8 ng/L predict all-cause mortality and cardiovascular events in patients treated with immune checkpoint inhibitors?
Does a follow-up high-sensitivity troponin I > 8 ng/L predict all-cause mortality and cardiovascular events in patients treated with immune checkpoint inhibitors?
In patients treated with immune checkpoint inhibitors, a follow-up high-sensitivity troponin I level >8 ng/L is an independent predictor of all-cause mortality and cardiovascular events.
May inform risk stratification in ICI-treated patients; hypothesis-generating for prospective validation.
BACKGROUND: Immune checkpoint inhibitors (ICIs) may lead to immune-related adverse events, including potentially life-threatening cardiovascular (CV) complications. Despite guideline-recommended troponin monitoring, limited data exist on evaluating its predictive significance. OBJECTIVE: We aimed to assess the predictive value of serial high-sensitivity troponin I (hs-TnI) monitoring in patients treated with ICIs. METHODS: A retrospective, single-center, observational study including patients treated with ICIs and performing serial hs-TnI measurements. The primary endpoint was all-cause mortality, and the secondary endpoint was CV events, defined as the composite of myocarditis, pericarditis, acute coronary syndrome, heart failure, or arrhythmias. A tree classifier model identified the most predictive hs-TnI concentration for the main study endpoints. RESULTS: Overall, 455 patients performed baseline (T1) and follow-up hs-TnI (T2) assessments and were included in the cohort. During a mean follow-up of 25 months (IQR [12-36]), 253 (56%) patients died, and 70 (15%) developed CV events. T2 > 8 ng/L was significantly associated with increased all-cause mortality (64% vs 48%, P < .001) and CV events (22% vs 9%, P < .001), notably HF (12% vs 4%, P = .003) and myocarditis (3% vs 0%, P = .038). A multivariable analysis confirmed that T2 > 8 ng/L was an independent predictor for all-cause mortality (HR 1.67, 95% CI: 1.29-2.17, P < .001) and CV events (HR 2.59, 95% CI: 1.50-4.46, P = .001). CONCLUSIONS: Our study emphasizes the significant role of serial troponin monitoring during ICIs therapy as an independent predictor of all-cause mortality and CV events, and suggests an optimal lower hs-TnI cutoff of >8 ng/L for risk stratification. Large prospective trials are needed to confirm these findings.
No takes yet. Share an insight, caveat, or question.
Perelman et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: