Highlights the rare but severe complication of intravascular hemolysis following mitral valve repair, which may necessitate reoperation and valve replacement.
Answers are grounded in this paper and cite their sources.
Prompts vigilance for hemolysis in post-repair anemia; single case leaves open incidence and prevention studies.
The case of a young patient who presented with severe hemolysis after mitral valve repair is presented. Valve repair included chordal shortening, transposition of chordae tendinae, and annular remodelling using a Duran flexible ring. Reoperation and valve replacement were required to control hemolytic anemia. The possible mechanisms leading to such an uncommon complication after plastic repair of the mitral valve are commented on. The scanty literature concerned is reviewed.
No takes yet. Share an insight, caveat, or question.
Mestres et al. (1992) studied this question.