Key result
Fontan fenestration occlusion raises oxygen saturation by ~11 points but reduces systemic blood flow.
Why the study?
Acute hemodynamic and oxygen delivery changes after temporary occlusion of atrial defects in patients post-fenestrated Fontan were evaluated to identify candidates for permanent closure.
Does temporary occlusion of atrial defects alter hemodynamics and oxygen delivery in patients after a fenestrated Fontan procedure?
Observational (n=14)
Does temporary occlusion of atrial defects alter hemodynamics and oxygen delivery in patients after a fenestrated Fontan procedure?
Answers are grounded in this paper and cite their sources.
Temporary occlusion of fenestrations after Fontan procedures improves arterial oxygenation but decreases systemic blood flow and overall oxygen delivery, leading to elevated resting oxygen extraction.
BACKGROUND Acute changes in hemodynamics and oxygen delivery accompanying temporary occlusion of atrial defects in 14 patients after a fenestrated Fontan procedure were evaluated at a median interval of 32 days after surgery to identify candidates for permanent transcatheter closure of their defects. METHODS AND RESULTS Patients ranged in age from 9 months to 33 years and in weight from 7.9 to 69 kg. Right atrial (RA), left atrial (LA), and aortic pressures, mixed venous (SmvO2) and aortic (SaO2) oxygen saturation, and whole-body oxygen consumption (VO2) were measured, and systemic blood flow (Qs), systemic oxygen transport (SOT), and oxygen extraction were calculated before and after occlusion. SmvO2, VO2, and RA pressures did not change, but SaO2 increased from 84 +/- 6% to 95 +/- 3% (p less than 0.05), and LA pressures fell from 5.1 +/- 3.6 to 3.7 +/- 2.2 mm Hg (p less than 0.05). Qs fell from 2.4 +/- 0.7 to 1.8 +/- 0.41.min-1.m-2 (p less than 0.05), SOT fell from 425 +/- 154 to 366 +/- 112 ml.O2.min-1.m-2 (p less than 0.05), and oxygen extraction increased from 0.40 +/- 0.12 to 0.46 +/- 0.13 (p less than 0.05). Only one patient did not undergo definitive closure of his defect because of a marked decrease in Qs and SOT with a significant rise in RA pressure. CONCLUSIONS Although delayed closure of an atrial defect in these patients improved morbidity and mortality, the complete separation of the venous and systemic circulations was accomplished at the expense of decreased Qs and oxygen delivery despite the improved level of arterial oxygenation. The resting levels of oxygen extraction are elevated and will be associated with decreased exercise capability. The long-term benefits of closure of these fenestrations are yet to be shown.
No takes yet. Share an insight, caveat, or question.
Hijazi et al. (1992) conducted an observational in Patients after fenestrated Fontan procedure (n=14). Temporary occlusion of atrial defects vs. Before occlusion (baseline) was evaluated on Aortic oxygen saturation (SaO2) (p=<0.05). Temporary occlusion of atrial defects after fenestrated Fontan improved aortic oxygen saturation but decreased systemic blood flow and oxygen transport.
Synapse has enriched 10 related papers. Consider them for comparative context: