Key result
The FastICA peel-off method efficiently removed ECG interference from multi-channel surface EMG signals, achieving high signal-to-interference ratios (12.6-13.4 dB) with minimal signal distortion.
Answers are grounded in this paper and cite their sources.
The FastICA peel-off method provides a practical solution for eliminating ECG interference from multichannel surface EMG recordings with minimal signal distortion.
BACKGROUND: Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. METHODS: A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surface EMG signals. Although demonstrating spatial variability in waveform shape, the ECG interference in different channels shares the same firing instants. Utilizing the firing information estimated from FastICA, ECG interference can be separated from surface EMG by a "peel off" processing. The performance of the method was quantified with synthetic signals by combining a series of experimentally recorded "clean" surface EMG and "pure" ECG interference. RESULTS: It was demonstrated that the new method can remove ECG interference efficiently with little distortion to surface EMG amplitude and frequency. The proposed method was also validated using experimental surface EMG signals contaminated by ECG interference. CONCLUSIONS: The proposed FastICA peel-off method can be used as a new and practical solution to eliminating ECG interference from multichannel EMG recordings.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2016) studied Amputation (transhumeral and transradial) (n=2). FastICA peel-off method vs. Contaminated EMG signals (unfiltered) was evaluated on Signal to interference ratio (SIR), median frequency variation ratio (MFVR), and correlation coefficient (CORR). The FastICA peel-off method efficiently removed ECG interference from multi-channel surface EMG signals, achieving high signal-to-interference ratios (12.6-13.4 dB) with minimal signal distortion.
Synapse has enriched 10 related papers. Consider them for comparative context: