Key result
ICA plus template subtraction mitigates ECG artifacts in multichannel EMG while better preserving low-frequency content.
Why the study?
ECG interference in EMG signals acquired near the heart hampers muscle fatigue evaluation in low-intensity contractions, and classic high-pass filtering attenuates valuable low-frequency EMG activity.
Does an automatic template subtraction and ICA approach improve the reduction of ECG interference in multichannel EMG signals compared to classic high-pass filtering?
Does an automatic template subtraction and ICA approach improve the reduction of ECG interference in multichannel EMG signals compared to classic high-pass filtering?
A novel signal processing methodology combining ICA and template subtraction effectively reduces ECG interference in EMG signals while preserving low-frequency content crucial for muscle fatigue assessment.
May enhance EMG fatigue assessment in low-intensity contractions; leaves open prospective clinical validation before routine use.
• EMG signals collected close to the heart may contain significant ECG interference. • This may hamper muscle fatigue evaluation, especially for low-contraction levels. • Methodology developed for reducing interference using template subtraction and ICA. • ECG components are automatically identified and no additional channel is required. • Low-frequency spectral content is preserved, which is valuable in fatigue analysis. Surface electromyography (EMG) can be used in the rehabilitation of musculoskeletal disorders, for evaluating the coordination of muscles that stabilize a joint, or as an objective tool in assessing muscle fatigue. This latter may be achieved by evaluating the low-frequency content of the EMG. However, the electrocardiogram (ECG) interference is also recorded when EMG is acquired close to the heart. It may mask or even modify the information of interest in the EMG. Different signal processing techniques have been proposed to eliminate ECG artifacts from the EMG signals, the high-pass filter being the most used one. Nevertheless, this classic filtering approach would also attenuate EMG activities below 30 Hz, which contain information from low-intensity muscle contractions. This work addresses the automatic ECG attenuation when multichannel EMG is collected on the left pectoralis major muscle during a muscle fatigue test. The proposed ECG artifact mitigation extends a successful automatic template subtraction (TS) approach, which does not require an extra reference channel and is now applied to independent EMG source signal components extracted using a blind source separation technique (ICA, Independent Component Analysis). The automatic detection of ECG components was performed through two alternative measures: entropy and Kullback-Leibler divergence. While the ECG interference seems to hamper the detection of muscle fatigue in the low-contraction regime, the association ICA+TS preserved better the EMG low-frequency content, and the entropy-based automatic detection was found to be more suitable, avoiding possible errors that might arise from manual detection procedures.
No takes yet. Share an insight, caveat, or question.
Costa et al. (2024) studied Muscle fatigue. Independent Component Analysis (ICA) combined with automatic template subtraction (TS) vs. High-pass filter (classic filtering approach) was evaluated on ECG artifact mitigation and preservation of EMG low-frequency content. The combination of Independent Component Analysis and automatic template subtraction effectively mitigated ECG artifacts in multichannel EMG while better preserving low-frequency content.