Key result
Post-procedure severe mitral regurgitation occurred at similar rates following percutaneous mitral balloon valvuloplasty with the multi-track balloon compared to the Inoue balloon.
Why the study?
The study was conducted to compare the frequency of severe mitral regurgitation following percutaneous mitral balloon valvuloplasty using the Inoue balloon versus the multi-track balloon technique.
Does the multi-track balloon technique reduce post-procedure severe mitral regurgitation compared to the Inoue balloon technique in patients undergoing percutaneous mitral balloon valvuloplasty for severe mitral stenosis?
Observational (n=470)
No
Does the multi-track balloon technique reduce post-procedure severe mitral regurgitation compared to the Inoue balloon technique in patients undergoing percutaneous mitral balloon valvuloplasty for severe mitral stenosis?
Both multi-track and Inoue balloon techniques are highly effective for percutaneous mitral balloon valvuloplasty, with similarly low rates of post-procedure severe mitral regurgitation.
Answers are grounded in this paper and cite their sources.
Similar severe MR rates support technique equivalence in this cohort; leaves open randomized validation for percutaneous mitral valvuloplasty.
Objectives: To compare the frequency of severe mitral regurgitation after percutaneous mitral balloon valvuloplasty (PMBV) via Inoue balloon and multi-track balloon technique in our population. Methodology: In this retrospective observational study which was conducted at a tertiary care cardiac center of Karachi, Pakistan between 2015 and 2020 on Hospital registry of PMBV patients. Data were categorized in to two groups, Inoue balloon or multi-track balloon technique. Post procedure echocardiographic and catheterization parameters and in-hospital outcomes and complications, including severe MR, were compared between two groups. Results: Out of 470 PMBV procedures, 286 (60.9%) were performed with multi-track and 184 (39.1%) with Inoue balloon. Improvement in mitral value area was significantly higher with multi-track as compared to Inoue balloon (0.66±0.31 cm2 vs. 0.56±0.29 cm2; p<0.001). Severe MR was not significant, 3.5% (10/286) vs. 4.3% (8/184); p=0.639 for multi-track and Inoue balloon. One patient in Inoue balloon group and two patients in multi-track group required emergency valve surgery. Stroke was observed in two patients of multi-track group and two patients from the same group developed tamponade. No in-hospital mortality was observed. Conclusion: Post-procedure severe MR is a significant and frequent complication. Rate of post procedure severe MR are similar for PMBV via Inoue balloon and multi-track balloon. Both methods are equally effective with equal success rate.
No takes yet. Share an insight, caveat, or question.
Farooq et al. (2022) conducted an observational in Severe mitral stenosis (n=470). Multi-track balloon technique vs. Inoue balloon technique was evaluated on Severe mitral regurgitation after procedure (p=0.639). Post-procedure severe mitral regurgitation occurred at similar rates following percutaneous mitral balloon valvuloplasty with the multi-track balloon compared to the Inoue balloon.
Synapse has enriched 10 related papers. Consider them for comparative context: