Key result
A low quantitative flow ratio (<0.80) in the jailed left circumflex artery after left main stenting significantly increased the 5-year risk of target lesion failure compared to a high QFR (HR 4.24).
Why the study?
The study was conducted to evaluate the impact of Murray law-based quantitative flow ratio of the jailed left circumflex coronary artery on long-term clinical outcomes after left main simple crossover stenting.
Does a low quantitative flow ratio (QFR < 0.80) in the jailed left circumflex artery predict 5-year target lesion failure in patients undergoing left main crossover stenting?
Cohort (n=164)
No
Does a low quantitative flow ratio (QFR < 0.80) in the jailed left circumflex artery predict 5-year target lesion failure in patients undergoing left main crossover stenting?
A low quantitative flow ratio (<0.80) in the jailed left circumflex artery after left main crossover stenting is an independent predictor of 5-year target lesion failure, suggesting QFR may help guide the need for additional side branch interventions.
Low jailed LCx QFR after LM crossover stenting was associated with higher 5-year TLF; hypothesis-generating for QFR-guided side branch intervention, needing prospective trials.
We aimed to evaluate the impact of new Murray law-based QFR of jailed left circumflex coronary artery (LCx) on long-term clinical outcomes after left main coronary artery (LM) simple crossover stenting. 164 patients who underwent LM-to-left anterior descending coronary artery simple crossover stenting and had appropriate angiographic view of LCx for QFR computation were enrolled. The primary clinical outcome was the 5-year target lesion failure (TLF), defined as a composite of cardiac death, a target vessel myocardial infarction or target lesion repeat revascularization. The mean QFR of the LCx after LM stent implantation was 0.88 ± 0.09, and 29 patients (17.7%) had a low QFR (< 0.80), which was significantly associated with a higher 5-year rate of TLF when compared with the high QFR group (27.6% vs. 6.7%; HR: 4.235; 95% CI 1.21-14.95; p = 0.0015). The 5-year LCx ostium-related TLR rate in the low QFR group was also higher (17.2% vs. 3.0% in the high QFR group; HR: 6.07, 95% CI 1.63-22.59, p = 0.002). In a multivariate Cox regression analysis, a low QFR in the LCx after LM stenting was an independent predictor of the 5-year TLF rate (HR: 3.21, 95% CI 1.21-8.53; p = 0.019). ROC analysis showed that QFR a negative predictive value (NPV) of 89.6% ([AUC] 0.73, 95% CI 0.58-0.88, p < 0.05), the cutoff point is 0.85. The patients with a low QFR (< 0.80) in jailed LCX after LM simple crossover stenting had worse 5-year outcomes than those with a high QFR. Conversely, a QFR ≥ 0.85 of jailed LCx could serve as a good predictor of low risk of adverse outcome in LCx ostium. The QFR computation of the jailed LCx may be helpful to determine whether an additional procedure is required for the jailed side branch.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) conducted a cohort in Left main coronary artery bifurcation lesions (n=164). Low quantitative flow ratio (< 0.80) in jailed LCx vs. High quantitative flow ratio (≥ 0.80) in jailed LCx was evaluated on 5-year target lesion failure (TLF), defined as a composite of cardiac death, target vessel myocardial infarction, or target lesion repeat revascularization (HR 4.24, 95% CI 1.21-14.95, p=0.0015). A low quantitative flow ratio (<0.80) in the jailed left circumflex artery after left main stenting significantly increased the 5-year risk of target lesion failure compared to a high QFR (HR 4.24).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: