Key result
High-speed atomic force microscopy revealed a two-step motion of the double-headed heavy meromyosin lever arm coupled to an 8.4 nm working stroke in the presence of ATP.
Why the study?
Due to technical limitations in visualizing rapid changes in nonprocessive molecular motors, mechanistic details in the force-generating steps of myosin II remain poorly understood.
High-speed atomic force microscopy reveals a two-step motion of the myosin II lever arm and provides mechanistic details of the power stroke at millisecond resolution.
Answers are grounded in this paper and cite their sources.
Does not inform clinical practice; leaves open translation of myosin dynamics to human cardiac function.
Myosin-based molecular motors are responsible for a variety of functions in the cells. Myosin II is ultimately responsible for muscle contraction and can be affected by multiple mutations, that may lead to myopathies. Therefore, it is essential to understand the nanomechanical properties of myosin II. Due to the lack of technical capabilities to visualize rapid changes in nonprocessive molecular motors, there are several mechanistic details in the force-generating steps produced by myosin II that are poorly understood. In this study, high-speed atomic force microscopy was used to visualize the actin–myosin complex at high temporal and spatial resolutions, providing further details about the myosin mechanism of force generation. A two-step motion of the double-headed heavy meromyosin (HMM) lever arm, coupled to an 8.4 nm working stroke was observed in the presence of ATP. HMM heads attached to an actin filament worked independently, exhibiting different lever arm configurations in given time during experiments. A lever arm rotation was associated with several non-stereospecific long-lived and stereospecific short-lived (∼1 ms) HMM conformations. The presence of free Pi increased the short-lived stereospecific binding events in which the power stroke occurred, followed by release of Pi after the power stroke.
No takes yet. Share an insight, caveat, or question.
Matusovsky et al. (2020) studied Myosin II dynamics. High-speed atomic force microscopy was evaluated on Conformational dynamics of skeletal myosin II power stroke. High-speed atomic force microscopy revealed a two-step motion of the double-headed heavy meromyosin lever arm coupled to an 8.4 nm working stroke in the presence of ATP.
Synapse has enriched 10 related papers. Consider them for comparative context: