Key result
On-table extubation after RAMT-AVR linked to ~1-day shorter hospital stay.
Why the study?
The safety profile of extubation in the operating room following aortic valve replacement via right anterior mini-thoracotomy has not been fully established.
Does routine on-table extubation in the operating room reduce ICU and hospital length of stay without increasing reintubation or morbidity compared to ICU extubation in patients undergoing isolated minimally invasive aortic valve replacement via right anterior mini-thoracotomy?
Cohort (n=423)
No
Does routine on-table extubation in the operating room reduce ICU and hospital length of stay without increasing reintubation or morbidity compared to ICU extubation in patients undergoing isolated minimally invasive aortic valve replacement via right anterior mini-thoracotomy?
Routine on-table extubation in the operating room is feasible and safe in nearly three-quarters of patients undergoing minimally invasive isolated aortic valve replacement via right anterior mini-thoracotomy, shortening ICU and hospital stays without increasing reintubation or 30-day mortality.
Answers are grounded in this paper and cite their sources.
Supports shorter ICU/hospital stays after RAMT-AVR; leaves open whether routine on-table extubation improves outcomes in randomized trials.
Objective: The present study aimed to evaluate the feasibility and safety of performing extubation in the operating room following aortic valve replacement (AVR) via right anterior mini-thoracotomy (RAMT), as the safety profile of this approach has not been fully established. Methods: We conducted a retrospective analysis of patients who underwent isolated AVR through a RAMT between February 2012 and December 2023. Emergency cases and reoperations were excluded. Patients were categorized according to the location of extubation—either in the operating room (on-table) or in the intensive care unit (ICU). Multivariable logistic regression analysis was used to identify predictors associated with successful on-table extubation. Results: Among 423 patients who underwent non-emergent isolated AVR, 73.3% were extubated in the operating room. This group was characterized by younger age, lower EuroSCORE II, and higher preoperative serum albumin levels. While the surgical techniques did not differ between groups, those extubated on-table had significantly shorter cardiopulmonary bypass times (84.0 [68.0–104.0] vs. 104.0 [85.0–131.5], p < 0.001). Although early postoperative outcomes were comparable, the on-table extubation group had significantly shorter ICU stays (24.0 [22.0–26.0] vs. 25.0 [23.0–30.0], p < 0.001) and hospital stays (5.0 [4.0–6.0] vs. 6.0 [5.0–8.0], p < 0.001). A predictive model incorporating age, albumin levels, and cardiopulmonary bypass time demonstrated a predictive accuracy of approximately 78.4% for on-table extubation success. Conclusions: Extubation in the operating room was found to be both safe and effective for the majority of patients undergoing isolated AVR via RAMT. It was associated with low reintubation rates and significantly reduced lengths of ICU and hospital stays. These findings support the adoption of routine on-table extubation in suitable patients undergoing this procedure.
No takes yet. Share an insight, caveat, or question.
Lim et al. (2025) conducted a cohort in Aortic valve disease requiring non-emergent isolated aortic valve replacement via right anterior mini-thoracotomy (n=423). On-table extubation in the operating room vs. Extubation in the intensive care unit (ICU) was evaluated on Length of hospital stay (days) (p=<0.001). On-table extubation in the operating room was achieved in 73.3% of RAMT-AVR patients and reduced median ICU stay and hospital stay.
Synapse has enriched 10 related papers. Consider them for comparative context: