Key result
The Ekblom-Bak submaximal cycle test detected longitudinal changes in VO2max over 5 to 8 years with good precision, showing a strong correlation with directly measured changes.
Why the study?
To examine the ability of a submaximal cycling test to detect longitudinal changes in VO2max and assess conformity between measured and estimated VO2max over 5–8 years.
Does the Ekblom-Bak submaximal cycle test accurately detect longitudinal changes in VO2max compared to direct measurement via maximal treadmill testing in healthy adults?
Cohort (n=35)
No
Does the Ekblom-Bak submaximal cycle test accurately detect longitudinal changes in VO2max compared to direct measurement via maximal treadmill testing in healthy adults?
Answers are grounded in this paper and cite their sources.
The Ekblom-Bak submaximal cycle test can detect longitudinal changes in VO2max with reasonably good precision over a 5-8 year period in healthy adults.
Background The purpose of the present study was to examine the ability of a submaximal cycling test to detect longitudinal changes in maximal oxygen uptake (VO 2 max) and examine the conformity between changes in measured and estimated VO 2 max over a time span of 5–8 years. Methods A total of 35 participants (21 men and 14 women), aged 29 to 63 years, performed the Ekblom-Bak (EB) submaximal cycle test for estimation of VO 2 max and a maximal treadmill running test for direct measurement of VO 2 max. The baseline tests were conducted between 2009 and 2012, and the follow-up tests were completed 5 to 8 years later. Pearson’s coefficient of correlation ( r ) and paired sample t -test were used to analyse the association between change in measured and estimated VO 2 max. Random and systematic errors between the measured and estimated VO 2 max were evaluated using Bland-Altman plots. Repeated measures ANOVA were used to test differences between changes over time. Results There was no significant change in mean measured VO 2 max between baseline and follow-up ( p = 0.91), however large individual variations were noted (− 0.78 to 0.61 L/min). The correlation between individual change in measured and estimated VO 2 max was r = 0.75 ( p < 0.05), and the unstandardised B-coefficient from linear regression modelling was 0.88 (95% CI 0.61 to 1.15), i.e., for each litre of change in estimated VO 2 max, the measured value had changed 0.88 L. The correlation between baseline and follow-up errors (the difference between estimated-measured VO 2 max at each occasion) was r = 0.84 ( p < 0.05). With regard to the testing procedure, repeated measures ANOVA revealed that there was no significant difference between the group who exercised at the same work rates at baseline and follow-up (n = 25), and those who required a change in work rate (n = 10). Conclusions The EB test detected a change in VO 2 max with reasonably good precision over a time span of 5–8 years. Further studies are needed to evaluate if the test can be used in clinical populations and in subjects with different medications.
No takes yet. Share an insight, caveat, or question.
Björkman et al. (2021) conducted a cohort in Healthy adults (n=35). Ekblom-Bak (EB) submaximal cycle test vs. Maximal treadmill running test (direct measurement) was evaluated on Association between change in measured and estimated VO2max (B-coefficient 0.88, 95% CI 0.61 to 1.15, p=< 0.05). The Ekblom-Bak submaximal cycle test detected longitudinal changes in VO2max over 5 to 8 years with good precision, showing a strong correlation with directly measured changes.
Synapse has enriched 10 related papers. Consider them for comparative context: