Answers are grounded in this paper and cite their sources.
Dual three-phase machines are becoming increasingly popular due to advantages such as inherent fault tolerant capability and lower current per phase for a given power. As in three-phase machines, it is important to provide thermal protection, in order to prevent reduction of the lifetime. Proposals specifically targeted to dual three-phase machines for estimating the stator winding temperature, and thus, avoiding the installation of thermal sensors, have not been reported so far. Concerning three-phase machines, previous publications have proposed techniques based on injecting a dc signal for estimating the stator winding temperature. However, a certain torque ripple is caused during the injection period, giving rise to a tradeoff between the magnitude of such ripple and the accuracy of the temperature estimation. This paper presents a method based on dc-signal injection for stator winding temperature estimation in dual three-phase machines with sinusoidally distributed windings and driven by field-oriented control. By applying the signal to the x-y plane, which is available in this type of machines and does not produce air-gap flux, no torque ripple is generated. Experimental results validate the proposed technique.
No takes yet. Share an insight, caveat, or question.
Baneira et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: