Key result
A positive adenosine test and low peripheral adenosine levels were associated with more frequent asystolic episodes during ILR monitoring.
Why the study?
The study was conducted to evaluate the relationship between adenosine levels, adenosine test outcomes, and implantable loop recorder monitoring findings in patients with syncope.
Do adenosine levels and the adenosine test predict asystolic episodes during ILR monitoring in patients with unexplained syncope?
Observational (n=29)
Do adenosine levels and the adenosine test predict asystolic episodes during ILR monitoring in patients with unexplained syncope?
A positive adenosine test and low endogenous adenosine levels are associated with more frequent asystolic episodes during ILR monitoring in patients with unexplained syncope.
Answers are grounded in this paper and cite their sources.
Positive adenosine test associated with more asystole on ILR; hypothesis-generating and should not yet change syncope evaluation.
Background Adenosine test was proposed as a tool for identification of syncopal patients who benefit from pacemaker implantation. Aim of the study was to assess the relationship between adenosine levels, the outcome of adenosine test and results of implantable loop recorder (ILR) monitoring in patients with syncope. Methods In 29 patients (mean age 59 ± 11 years, 15 men, 14 women) with unexplained syncope ILR was implanted. In addition, adenosine test (intravenous injection of 20 mg adenosine bolus) and assays of plasmatic adenosine and adenosine‐deaminase were performed. Results Adenosine test was positive in 15 patients and negative in 14 patients. Patients with positive adenosine test had lower adenosine levels compared to patients with negative test (8.86 ± 2.07 ng/ml vs. 15.18 ± 2.14 ng/ml, p = .04). No difference was observed in adenosine deaminase levels (16.35 ± 2.20 IU/l vs. 13.20 ± 2.48 IU/l, p = .40). There was a negative correlation between adenosine level and AVB duration during adenosine test (p = .04; R2 = 0.22). Patients with positive adenosine test had more frequent asystole during ILR monitoring than patients with negative test (9 pts vs. 1 pt, p = .005). Adenosine levels were lower in patients with asystolic syncope on ILR compared to vasodepressor syncope 8.20 ± 2.86 ng/ml versus 13.27 ± 7.26 ng/ml, p = .05). Conclusions Patients with positive adenosine test have decreased production of endogenous adenosine compared to patients with negative adenosine test. Positivity of adenosine test and low adenosine level in the peripheral blood were associated with more frequent asystolic episodes during ILR monitoring.
No takes yet. Share an insight, caveat, or question.
Mitro et al. (2022) conducted an observational in unexplained syncope (n=29). Positive adenosine test vs. Negative adenosine test was evaluated on asystole during ILR monitoring (p=0.005). A positive adenosine test and low peripheral adenosine levels were associated with more frequent asystolic episodes during ILR monitoring.
Synapse has enriched 10 related papers. Consider them for comparative context: