Answers are grounded in this paper and cite their sources.
A significant proportion of the total weight in a large spaceborne electrical power plant is associated with the radiator. The belt space radiator offers a concept in the rcjcctdon of heat in a space environment that may theoretically reduce the radiator weight by more than 60% if thermal contact resistance between the revolving belt and heat source drum is sufficiently small. A theoretical analysis of thc effects of contact resistance on optimum weight applicable to a revolving belt radiator with a stationary condenser drum, as well as to a system with revolving condenser drum and geometrically stationary belt configuration for,a 1-megawatt power output system, is given. It is found that the effective contact heat transfer film coefficient must be approximately 400 Btu/hr-ft/sup 2/- deg F to realize significant weight savings. If this value of film coefficient can be obtained, the belt radiator must be considered as a replacement for conventional header and tube radiators for spaceborne power plants. (auth)
No takes yet. Share an insight, caveat, or question.
H. L. Burge (1962) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: