In the double spectrometer used, x-radiation was reflected from a crystal surface A through a slit S on to a second crystal surface B, and thence to the ionization chamber. Surfaces A and B were obtained by splitting a single crystal of calcite. The curve obtained for Mo Kα by rocking B is a triangle with base about 8 seconds wide. The effect of interposing a prism of aluminum (angle 166^∘{}) between S and B was to shift the curve 5.62{''} on the average, giving 1-μ=1.68×10^-6. The value calculated from the Lorentz dispersion formula is 1.77×{}10^-6. For Cu Kα the shift was 5.53{''} for a 116^∘{} prism, giving 1-μ=8.4×10^-6 as compared with the calculated value 8.36×{}10^-6. The accuracy of this method is thus within 5 percent.