Butter may be adulterated with cheaper animal fats, such as chicken fat (CF). Thus, the detection and quantification of butter adulteration with CF was monitored using Fourier transform infrared (FTIR) spectroscopy, combined with chemometric of partial least square (PLS) at the frequency regions of 1200-1000cm–1. FTIR measurements were made on pure butter and that adulterated with varying concentrations of CF (0-100% w/w in butter). PLS calibration exhibits a good relationship between actual and FTIR predicted values of CF with a coefficient of determination (R2) of 0.981. The root means standard error of calibration (RMSEC) and during cross validation (RMSECV) obtained using six principal components (PCs) are 2.08 and 4.33% v/v, respectively.
No takes yet. Share an insight, caveat, or question.
Nurrulhidayah et al. (2013) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: