Answers are grounded in this paper and cite their sources.
A special method is introduced for quantitatively determining the metal-evaporation mechanism using metallic gold and chromium tagged with pile-produced Au198 and Cr51. This tracer method provides a powerful tool for the study of the distribution of minute amounts of the evaporated metal. Propagation and deposition of the vaporized metal are analyzed under a variety of conditions both in the normal evaporation process and for shadow-casting conditions. It is shown that crucible size and shape determine the evaporation-dispersion pattern. Computation of film thickness is by quantitative tracer methods with correlating observations by electron microscopy. Structure of these metal films correlates with observations by an earlier worker [R. W. G. Wyckoff, PSA Journal 13, 12 (1947)]. The probable error of the method is ±2 percent.
No takes yet. Share an insight, caveat, or question.
Luther E. Preuss (1953) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: